Performing SDR on dissimilar hardware
book
Article ID: 100063158
calendar_today
Updated On:
Description
Error Message
Drivers for the following controllers cannot be found on the restored computer.
Cause
Attempting to restore a server from a workstation backup.
Resolution
To resolve the issue of the storage controller driver failing to install during Simplified Disaster Recovery on dissimilar hardware, change the BIOS setting from 'RAID' to 'AHCI'.
- Restart the Server
- During the boot process, enter the BIOS settings by pressing the designated key (usually F2 or Del).
- Navigate to the 'Storage' or 'SATA Configuration' section in the BIOS.
- Locate the 'RAID' or 'Storage Configuration' option and select it.
- Change the setting from 'RAID' to 'AHCI'.
- Save the changes and exit the BIOS.
- Proceed with the Simplified Disaster Recovery process again.
- The storage controller driver should now be able to install successfully.
- Continue with the restoration process as usual.
Issue/Introduction
Error Code/Message
Was this article helpful?