Any or all of the following errors may appear. The referenced .dll file may also be different than what is shown:
The application has failed to start because api-ms-win-core-localization-l1-2-0.dll was not found. Re-installing the application may fix this problem.
The application has failed to start because api-ms-win-core-io-l1-1-0.dll was not found. Re-installing the application may fix this problem.
Clicking OK on one of the above 2 messages results in an APPCRASH:
Boot Configuration Data Editor has stopped working.
Windows can check online for a solution to the problem.
Problem signature:
Problem Event Name: APPCRASH
Application Name: bcdedit.exe
Application Version: 10.0.16299.15
Fault Module Name: api-ms-win-core-localization-l1
Fault Module Version: 6.0.6002.24282
Exception Code: c0000135
Exception Offset: 00009f7d
OS Version: 6.0.6002.2.2.0.272.7
Locale ID: 1033
Additional Information 1: 9d13
Additional Information 2: 1abee00edb3fc1158f9ad6f44f0f6be8
Additional Information 3: 9d13
Additional Information 4: 1abee00edb3fc1158f9ad6f44f0f6be8
At the end of the process the final error code will be:
ECA31B77: Failed to install LightsOut Restore on this system
The BCD will now contain bad entries pointing to a temporary folder used for the LightsOut Restore setup process. If the system is booted with these settings, one of the bad "Windows Preinstallation Environment" entries may be set as the Default. Unless the user intervenes and selects the correct "Microsoft Windows Server 2008" entry, the system will fail to boot with error 0xc000000f:
Incompatibility between ADK 10 and Windows Server 2008 x86.
1. From Programs and Features in the Control Panel, uninstall "Windows Assessment and Deployment Kit - Windows 10"
2. Clean up invalid BCD entries using BCDEDIT (including setting Default to the correct entry)
3. Reboot to confirm system boots properly
4. Install the Windows ADK 8.1 from Microsoft:
https://go.microsoft.com/fwlink/p/?LinkId=393005
5. Create a new SRD using Advanced option and select the option to install LightsOut Restore
Veritas Technologies LLC has acknowledged that the above-mentioned issue is present in the current version(s) listed under the Product(s) Section of this article. Veritas Technologies LLC is committed to product quality and satisfied customers.
This issue is currently under investigation by Veritas Technologies LLC. Pending the outcome of the investigation, this issue may be resolved by way of a patch or hotfix in current or future revisions of the software. However, this particular issue is not currently scheduled for any release. If you feel this issue has a direct business impact for you and your continued use of the product, please contact your Veritas Sales representative or the Veritas Sales group to discuss these concerns. For information on how to contact Veritas Sales, please see http://www.veritas.com.
Please be sure to refer back to this document periodically as any changes to the status of the issue will be reflected here.