The following may be seen in the
YYYY/MM/DD HH:MM:SS - Error- Errorcode = 3970107346, Error Description= Error Veritas System Recovery Disk change Failed to open WIM file in staging area (mount or apply). Microsoft's platform code is% 1.
YYYY/MM/DD HH:MM:SS - Error- Task failed : Error ECA307D2: Veritas System Recovery Disk change Failed to open WIM file in staging area (mount or apply). Microsoft's platform code is% 1.
YYYY/MM/DD HH:MM:SS - Info- Telemetry=product=SSR&version=16.0&language=ja-JP&module=BKUPEXEC&error=SSR_SRD_CREATE_1_1&upgrade=&build=16.0.2.56166&addon=&hotfix=&MID=7c38ab54-ab06-4aab-9d9d-41b5377dee12&OS=Windows 10&a=1&b=0&c=0.0&d=0&e=2&f=&g=10.0.10240&h=0&i=2&j=ECA307D2&k=1&l=1
YYYY/MM/DD HH:MM:SS - Error-
Source:
interop.VProTelemetrySend
Message:
Exception from HRESULT :0x80072EE7
Stack Trace:
Location VProTelemetrySend.TelemetrySendClass.SendDataToServer(String Data, String InternalServerSite, String InternalServerUrl, String ExternalServerSite, String ExternalServerUrl, Int32 RetrySend)
Location Symantec.UI.Common.TelemetryHelper.SendTelemetryData(String data)
YYYY/MM/DD HH:MM:SS - Info- [HH:MM:SS] - Creation operation failed...Error ECA307D2: Veritas System Recovery Disk Veritas System Recovery Disk change Failed to open WIM file in staging area (mount or apply) . Microsoft's platform code is% 1.
This issue is reported on Windows 10 64bit RTM (Build 1507).
1. Run Windows Update and apply the latest updates.
2. Upgrade VSR to version VSR 21 or above: Step By Step guide to download and install Veritas System Recovery
3. Run 'Recovery Disk Creation Wizard' with option "Run as different user" - using domain admin account.
4. Run SRD creation wizard on the other machines that have OS version except Windows 10 64bit RTM (Build 1507).
5. Run SRD creation wizard with Advanced mode after applying ADK 10 (Build 1507).