Error reported:
A device attached to the system is not functioning.
V-79-57344-34036 - An unknown error has occurred.
NDMP log shows the following errors:
NDMP Log Message: DUMP: Wed Dec 17 23:31:43 2008 : We have written 226664 KB.
NDMP Log Message: DUMP: dumping (Pass IV) [regular files]
NDMP Log Message: DUMP: Tape write failed.
NDMP Log Message: DUMP: DUMP IS ABORTED
NDMP Log Message: DUMP: Deleting "/vol/vol0/../snapshot_for_backup.10" snapshot.
NDMP Data Halted: Connect Error
NDMP Log Message: Connection or IO Error.
NDMP Mover Halted: Internal Error
NDMP Log Message: MoveletOutput: Internal Error.
On a NetApp/IBM filer running the ONTAP operating system, you can optimize performance for either minimal transmission delay or throughput. By default, the performance is optimized for overall throughput, in which the packets are grouped in time blocks of 200 ms. If the communication performance is optimized for minimal transmission delay, the queued packets are sent immediately.